Part Details | RADIAC SET
6665-00-526-8648 A fixed number of components and/or items, not all having the same basic name, which are used to detect, measure and/or compute radioactivity. They may or may not indicate simultaneously.
Alternate Parts: ANPDR39A, M1LR10060, MILR10060, 723800, MILR10060, ANPDR39A, M1LR10060, MILR10060, 6665-00-526-8648, 00-526-8648, 6665005268648, 005268648
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | JAN 01, 1963 | 00-526-8648 | 07331 ( RADIAC SET ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6665-00-526-8648
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| ANPDR39A | 80058 | JOINT ELECTRONICS TYPE DESIGNATIONSYSTEM |
| M1LR10060 | 80058 | JOINT ELECTRONICS TYPE DESIGNATIONSYSTEM |
| MILR10060 | 80058 | JOINT ELECTRONICS TYPE DESIGNATIONSYSTEM |
| 723800 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MILR10060 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| ANPDR39A | 04926 | PIASECKI AIRCRAFT CORPORATIONDBA P I A C |
| M1LR10060 | 04926 | PIASECKI AIRCRAFT CORPORATIONDBA P I A C |
| MILR10060 | 04926 | PIASECKI AIRCRAFT CORPORATIONDBA P I A C |
Technical Data | NSN 6665-00-526-8648
| Characteristic | Specifications |
|---|---|
| RADIATION TYPE AND FUNCTION | GAMMA RAYS MEASURES |
| RADIATION RANGE PER HOUR | +0.0 TO +50.0 ROENTGENS |
| ACCURACY IN PERCENT | -15.0 TO +15.0 ALL RANGES |
| ENERGY DEPENDENCE RATING | +0.080 TO +1.500 MEV |
| INDICATOR TYPE | CJ ANY ACCEPTABLE |
| DETECTING ELEMENT TYPE | C ANY ACCEPTABLE |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 3.0 DC |
| INTERNAL BATTERY ACCOMMODATION | INCLUDED |
| JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME | RADIAC SET |
| JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER | AN/PDR-39A |