Part Details | FLOW CONTROL THERMOSTAT
6685-00-424-6470 An automatic regulating device which controls the flow of fluids or gases by actuating a valve or shutter for heating or cooling purposes. May be adjustable, or set to operate at a definite pressure. Excludes CONTROL, HUMIDITY; CONTROL, TEMPERATURE INDICATING; and SWITCH, THERMOSTATIC.
Alternate Parts: 044873, 00448738, 0044873-8, 0044873, 6685-00-424-6470, 00-424-6470, 6685004246470, 004246470
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | JAN 01, 1963 | 00-424-6470 | 16516 ( THERMOSTAT, FLOW CONTROL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-00-424-6470
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 044873 | 89926 | NEW HOLLAND CONSTRUCTION |
| 0044873-8 | 89926 | NEW HOLLAND CONSTRUCTION |
| 0044873 | 89926 | NEW HOLLAND CONSTRUCTION |
Technical Data | NSN 6685-00-424-6470
| Characteristic | Specifications |
|---|---|
| THERMOSTAT TYPE | B ANY ACCEPTABLE |
| USAGE DESIGN | CONTROL ENGINE COOLANT TEMP |
| MOUNTING METHOD | F ANY ACCEPTABLE |
| OPENING TEMP RATING | 180.0 DEG FAHRENHEIT NOMINAL |
| OPERATING TEMP RATING | 210.0 DEG FAHRENHEIT NOMINAL |
| SPRING OPERATED PRESSURE RELIEF | NOT PROVIDED |
| VALVE TRAVEL DISTANCE | 0.313 INCHES MINIMUM AND 0.375 INCHES MAXIMUM |
| FLOW CONTROL DEVICE | CHOKE |
| LARGEST OUTSIDE DIAMETER | 2.551 INCHES NOMINAL |
| OVERALL HEIGHT | 2.250 INCHES MINIMUM AND 2.265 INCHES MAXIMUM |
| FSC APPLICATION DATA | ENGINE |