Part Details | DIAL INDICATING DIFFERENTIAL GAGE
6685-00-451-6287 An instrument designed to measure air, gas, fluid, and vapor differential by means of a pressure sensitive element(s) which transmits energy, by direct linkage, to the indicating pointer of a scale calibrated to units of pressure. The scale may indicate in units of pressure, quantity, or flow.
Alternate Parts: 07EBXXX0400E1AXXXX01, 6685-00-451-6287, 00-451-6287, 6685004516287, 004516287
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | MAY 27, 1971 | 00-451-6287 | 62209 ( GAGE, DIFFERENTIAL, DIAL INDICATING ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-00-451-6287
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 07EBXXX0400E1AXXXX01 | 05991 | CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS |
Technical Data | NSN 6685-00-451-6287
| Characteristic | Specifications |
|---|---|
| ACTUATION TYPE | BELLOWS |
| ACTUATING ELEMENT MATERIAL | BERYLLIUM COPPER |
| SCALE TYPE | SINGLE |
| SCALE NAME | DIFFERENTIAL PRESSURE |
| SCALE RANGE | +0.0 TO +400.0 POUNDS PER SQUARE INCH |
| MATERIAL | ALUMINUM |
| POINTER COLOR | WHITE |
| CONNECTOR TYPE VENT | NOT PROVIDED |
| SCALE ACCURACY | 3/4 PCT. ENTIRE RANGE |
| SCALE INSCRIPTION/BACKGROUND COLOR | WHITE FIGURES ON BLACK BACKGROUND |
| DIAL SIZE | 6 IN. DIA. |
| POINTER TYPE | INDICATING |
| ADJUSTABILITY | ADJUSTABLE |
| CASE MATERIAL | ALUMINUM, DIE CAST |
| CASE SURFACE TREATMENT | PAINT, EPOXY |
| OVERALL DIAMETER | 7.500 INCHES NOMINAL |
| OVERALL DEPTH | 4.671 INCHES NOMINAL |
| BEZEL TYPE | NB ANY ACCEPTABLE |
| PROTECTIVE CRYSTAL MATERIAL | GLASS |
| CONNECTION QUANTITY | 2 |
| CONNECTION TYPE | INTERNAL |
| CONNECTION LOCATION | YM ANY ACCEPTABLE AND LOWER |
| CONNECTION SIZE | 0.250 IN. NPT DIA |
| MOUNTING METHOD | FLUSH PANEL |
| BOLT CIRCLE DIAMETER | 7.000 INCHES NOMINAL |
| MOUNTING HOLE QUANTITY | 4 |
| MOUNTING HOLE DIAMETER | 0.266 INCHES NOMINAL |