Part Details | FLOW CONTROL THERMOSTAT
6685-00-508-1490 An automatic regulating device which controls the flow of fluids or gases by actuating a valve or shutter for heating or cooling purposes. May be adjustable, or set to operate at a definite pressure. Excludes CONTROL, HUMIDITY; CONTROL, TEMPERATURE INDICATING; and SWITCH, THERMOSTATIC.
Alternate Parts: 552559, VD10915, 8735512, 6685-00-508-1490, 00-508-1490, 6685005081490, 005081490
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | JAN 01, 1963 | 00-508-1490 | 16516 ( THERMOSTAT, FLOW CONTROL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-00-508-1490
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 552559 | 02978 | L3 TECHNOLOGIES, INC.DBA COMBAT PROPULSION SYSTEMS |
| VD10915 | 55193 | ROSTRA VERNATHERM, LLCDBA BILBE CONTROLS |
| 8735512 | 19207 | U S ARMY TANK AUTOMOTIVE COMMANDAMSTA-IM-MM |
Technical Data | NSN 6685-00-508-1490
| Characteristic | Specifications |
|---|---|
| THERMOSTAT TYPE | E ANY ACCEPTABLE |
| USAGE DESIGN | ENGINE OIL COOLER |
| MOUNTING METHOD | THREADED |
| OPENING TEMP RATING | 90.0 DEG FAHRENHEIT NOMINAL |
| OPERATING TEMP RATING | 140.0 DEG FAHRENHEIT MINIMUM AND 144.0 DEG FAHRENHEIT MAXIMUM |
| SPRING OPERATED PRESSURE RELIEF | PROVIDED |
| OPENING PRESSURE SETTING | 80.0 POUNDS PER SQUARE INCH |
| VALVE TRAVEL DISTANCE | 0.190 INCHES MINIMUM |
| FLOW CONTROL DEVICE | BY-PASS |
| DISTANCE ACROSS FLATS | 1.750 INCHES NOMINAL |
| THREAD SIZE AND SERIES/TYPE DESIGNATOR | 1 7 TO 16-12 UN |
| THREAD DIRECTION | RIGHT-HAND |
| INSIDE MOUNTING SURFACE TO VALVE SEAT DISTANCE | 3.440 INCHES |