NSN 6685-00-527-6113

Part Details | DIAL INDICATING PRESSURE GAGE

6685-00-527-6113 An instrument designed to measure air, gas, fluid, and vapor pressure by means of an internal pressure sensitive element (bellows, bourdon tube, transducer/transmitter and the like) which transmits energy, by direct linkage, to the indicating pointer of a scale or a digital display, calibrated in units of pressure. It may include a temperature equivalent scale. For items that do not have an internal pressure sensitive element see INDICATOR, PRESSURE.

Alternate Parts: 2 12 5DFM18CBM3000RB, 2 1-2 5DFM1-8CBM3000RB, 2 12 5DFM18CBM3000RB, 2 1-2 5DFM1-8CBM3000RB, 2001117, 2001-117, 020010117, 02001-0117, 6685-00-527-6113, 00-527-6113, 6685005276113, 005276113

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JAN 01, 196300-527-611307428 ( GAGE, PRESSURE, DIAL INDICATING )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-00-527-6113
Part Number Cage Code Manufacturer
2 1-2 5DFM1-8CBM3000RB01170BELLOFRAM CORPORATIONDBA MARSH-BELLOFRAM
2 1-2 5DFM1-8CBM3000RB38508DESCO CORPMARSH BELLOFRAM DIV
2001-11793568HARSCO CORPBMY-COMBAT SYSTEMS DIV
02001-011793568HARSCO CORPBMY-COMBAT SYSTEMS DIV
Technical Data | NSN 6685-00-527-6113
Characteristic Specifications
ACTUATION TYPE SINGLE BOURDON TUBE
ACTUATING ELEMENT MATERIAL COPPER ALLOY
SCALE TYPE SINGLE
SCALE NAME PRESSURE
SCALE RANGE+0.0 TO +3000.0 POUNDS PRESSURE PER SQUARE INCH
SCALE ACCURACY1 PCT ENTIRE RANGE
GRADUATION UNIT300.0 POUNDS PER SQUARE INCH
SCALE SMALLEST INCREMENT100.0 POUNDS PER SQUARE INCH
SCALE INSCRIPTION/BACKGROUND COLORBLACK FIGURES,RED ARC FROM 1800 TO 3000 PSI,WHITE BACKGROUND
DIAL SIZE2-1/2 IN. DIA
SCALE MARKING3RD STAGE PRESSURE
POINTER TYPE INDICATING
ADJUSTABILITY ADJUSTABLE
POINTER COLOR BLACK
CASE MATERIAL STEEL
CASE SURFACE TREATMENT ENAMEL
OVERALL DIAMETER2.781 INCHES NOMINAL
OVERALL DEPTH1.172 INCHES NOMINAL
PROTECTIVE CRYSTAL MATERIAL GLASS
CONNECTION QUANTITY1
CONNECTION TYPE EXTERNAL
CONNECTION LOCATIONZ ANY ACCEPTABLE
CONNECTION SIZE1/8 IN. NPT
MOUNTING METHODRY ANY ACCEPTABLE AND E ANY ACCEPTABLE AND BC ANY ACCEPTABLE
STUD QUANTITY2
STUD LOCATION
CONNECTOR TYPE VENT NOT PROVIDED
USAGE DESIGNW/STEAM OR WATER
FSC APPLICATION DATAGAGE PRESSURE,DIAL INDICATING EXCEPT ENGINE