NSN 6685-00-801-5766

Part Details | DIAL INDICATING PRESSURE GAGE

6685-00-801-5766 An instrument designed to measure air, gas, fluid, and vapor pressure by means of an internal pressure sensitive element (bellows, bourdon tube, transducer/transmitter and the like) which transmits energy, by direct linkage, to the indicating pointer of a scale or a digital display, calibrated in units of pressure. It may include a temperature equivalent scale. For items that do not have an internal pressure sensitive element see INDICATOR, PRESSURE.

Alternate Parts: 75B3365, 75B33-65, 176F33, 6685-00-801-5766, 00-801-5766, 6685008015766, 008015766

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JAN 01, 196200-801-576607428 ( GAGE, PRESSURE, DIAL INDICATING )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-00-801-5766
Part Number Cage Code Manufacturer
75B33-6572100LIFTEC INCDIV LIFTEC, INC.
176F3372100LIFTEC INCDIV LIFTEC, INC.
Technical Data | NSN 6685-00-801-5766
Characteristic Specifications
ACTUATION TYPE SINGLE BOURDON TUBE
ACTUATING ELEMENT MATERIAL STEEL, AISI 316
SCALE TYPE SINGLE
SCALE NAME PRESSURE
SCALE RANGE+0.000 TO +300.000 POUNDS PRESSURE PER SQUARE INCH
SCALE ACCURACY1/2 OF 1 PCT ENTIRE RANGE
GRADUATION UNIT30.0 POUNDS
SCALE SMALLEST INCREMENT5.0 POUNDS
SCALE INSCRIPTION/BACKGROUND COLORBLACK NUMERALS AND GRADUATING MARKS ON ETCHED SILVERED BRASS BACKGROUND
DIAL SIZE6 IN. DIA
POINTER TYPE INDICATING
ADJUSTABILITY ADJUSTABLE
POINTER COLOR BLACK
CASE MATERIAL IRON
CASE SURFACE TREATMENT ENAMEL, BLACK
OVERALL DIAMETER7.875 INCHES NOMINAL
OVERALL DEPTH1.938 INCHES NOMINAL
MATERIAL STEEL
SURFACE TREATMENT ENAMEL
BEZEL TYPECS ANY ACCEPTABLE
PROTECTIVE CRYSTAL MATERIAL PLASTIC
CONNECTION QUANTITY1
CONNECTION TYPE EXTERNAL
CONNECTION LOCATION LOWER BACK
CONNECTION SIZE1/4 IN. NPT
MOUNTING METHOD FLUSH PANEL
BOLT CIRCLE DIAMETER6.875 INCHES NOMINAL
MOUNTING HOLE QUANTITY3
MOUNTING HOLE DIAMETER0.250 INCHES NOMINAL
CONNECTOR TYPE VENT NOT PROVIDED
SPECIAL FEATURESSAFETY FRONT
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSAS DIFFERENTIATED BY SCALE DATA,DIAL DATA,CASE,DATA,CONNECTION DATA,MTG DATA,SPECIAL FEATURES
FSC APPLICATION DATAGAGE,PRESSURE,DIAL INDICATING,EXCEPT ENGINE