NSN 6685-00-805-1847

Part Details | DIAL INDICATING PRESSURE GAGE

6685-00-805-1847 An instrument designed to measure air, gas, fluid, and vapor pressure by means of an internal pressure sensitive element (bellows, bourdon tube, transducer/transmitter and the like) which transmits energy, by direct linkage, to the indicating pointer of a scale or a digital display, calibrated in units of pressure. It may include a temperature equivalent scale. For items that do not have an internal pressure sensitive element see INDICATOR, PRESSURE.

Alternate Parts: 227, 6685-00-805-1847, 00-805-1847, 6685008051847, 008051847

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JAN 01, 196200-805-184707428 ( GAGE, PRESSURE, DIAL INDICATING )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-00-805-1847
Part Number Cage Code Manufacturer
22705991CAMERON TECHNOLOGIES US, INC.DBA CAMERON'S MEASUREMENT SYSTEMS
Technical Data | NSN 6685-00-805-1847
Characteristic Specifications
ACTUATION TYPE DOUBLE BELLOWS
ACTUATING ELEMENT MATERIAL BERYLLIUM COPPER
SCALE TYPE SINGLE
SCALE NAME PRESSURE
SCALE RANGE+0.0 TO +60.0 INCHES OF MERCURY
SCALE ACCURACY1/2 OF 1 PCT ENTIRE RANGE
GRADUATION UNIT5.0 INCHES
SCALE SMALLEST INCREMENT0.5 INCHES
SCALE INSCRIPTION/BACKGROUND COLORWHITE FIGURES ON BLACK BACKGROUND
DIAL SIZE6 IN. DIA
SCALE MARKINGINCHES OF MERCURY
POINTER TYPE INDICATING
ADJUSTABILITY ADJUSTABLE
POINTER COLOR WHITE
CASE MATERIAL ALUMINUM
CASE SURFACE TREATMENT ENAMEL
OVERALL DIAMETER6.375 INCHES NOMINAL
OVERALL DEPTH3.984 INCHES NOMINAL
MATERIAL ALUMINUM
SURFACE TREATMENT ENAMEL
BEZEL TYPENB ANY ACCEPTABLE
PROTECTIVE CRYSTAL MATERIAL GLASS
CONNECTION QUANTITY4
CONNECTION TYPE INTERNAL AND INTERNAL AND INTERNAL AND INTERNAL
CONNECTION LOCATIONYM ANY ACCEPTABLE AND YM ANY ACCEPTABLE AND LOWER AND LOWER
CONNECTION SIZE0.250 IN. NPT ALL CONNECTION
MOUNTING METHODRY ANY ACCEPTABLE AND E ANY ACCEPTABLE
BOLT CIRCLE DIAMETER7.000 INCHES NOMINAL
STUD QUANTITY4
STUD LOCATION
CONNECTOR TYPE VENT NOT PROVIDED
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSAS DIFFERENTIATED BY SCALE DATA,DIAL DATA,POINTER DATA,CONNECTION DATA
FSC APPLICATION DATAGAGE,PRESSURE,DIAL INDICATING,EXCEPT ENGINE