Part Details | IMMERSION THERMOCOUPLE
6685-00-915-2645 A thermocouple whose thermojunction is specifically designed to be placed or dipped within a fluid.
Alternate Parts: 21C2746P010, JP232581670184, JP23-2-5/8-16-7018-4, JP2302(58)16AF1B0184, JP23-02(5/8)-16A-F1B018-4, JP2302(58)16AF1A0184, JP23-02(5/8)-16A-F1A018-4, 2J3321U12IN18IN, 2J3321U1-2IN18IN, J8G304BAY902IN2 58IN18IN36IN, J8G304BAY90-2IN2 5-8IN18IN36IN, J18G304BAY902IN2 58183L, J18G-304-BAY90-2IN-2 5/8-18/3L, 6685-00-915-2645, 00-915-2645, 6685009152645, 009152645
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | JUL 06, 1966 | 00-915-2645 | 07117 ( THERMOCOUPLE, IMMERSION ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-00-915-2645
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 21C2746P010 | 07482 | GENERAL ELECTRIC COMPANYDBA GE |
| JP23-2-5/8-16-7018-4 | 1BW74 | PYROMATION INC |
| JP23-02(5/8)-16A-F1B018-4 | 1BW74 | PYROMATION INC |
| JP23-02(5/8)-16A-F1A018-4 | 1BW74 | PYROMATION INC |
| 2J3321U1-2IN18IN | 99195 | THERMO ELECTRIC COMPANY INC.DBA THERMO ELECTRIC TEMPERATURE |
| J8G304BAY90-2IN2 5-8IN18IN36IN | 99195 | THERMO ELECTRIC COMPANY INC.DBA THERMO ELECTRIC TEMPERATURE |
| J18G-304-BAY90-2IN-2 5/8-18/3L | 99195 | THERMO ELECTRIC COMPANY INC.DBA THERMO ELECTRIC TEMPERATURE |
Technical Data | NSN 6685-00-915-2645
| Characteristic | Specifications |
|---|---|
| UNIT TYPE | PROTECTIVE TUBE |
| OPERATING TEMP RANGE | +75.0 TO +1200.0 DEG FAHRENHEIT |
| IMMERSION LENGTH | 2.000 INCHES NOMINAL |
| ACCOMMODATED WIRE AWG SIZE | 22 |
| TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, PLUG |
| OVERALL LENGTH | 18.000 INCHES NOMINAL |
| SPECIAL FEATURES | 18 IN. LEADS TO PLUG CONNECTOR |