NSN 6685-00-989-4669

Part Details | DIAL INDICATING PRESSURE GAGE

6685-00-989-4669 An instrument designed to measure air, gas, fluid, and vapor pressure by means of an internal pressure sensitive element (bellows, bourdon tube, transducer/transmitter and the like) which transmits energy, by direct linkage, to the indicating pointer of a scale or a digital display, calibrated in units of pressure. It may include a temperature equivalent scale. For items that do not have an internal pressure sensitive element see INDICATOR, PRESSURE.

Alternate Parts: HL20010 PIECE, HL-20010 PIECE, 7027E64AB8, MILG18997, MIL-G-18997, DG4MC1HPWRANAG, 829N404FCRCW, 829N4-04FCRCW, SB243PFPRWBX, SB24-3PFP-RWBX, 6685-00-989-4669, 00-989-4669, 6685009894669, 009894669

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66NOV 04, 196600-989-466907428 ( GAGE, PRESSURE, DIAL INDICATING )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-00-989-4669
Part Number Cage Code Manufacturer
HL-20010 PIECE93232CURTISS-WRIGHT ELECTRO-MECHANICALCORPORATION
7027E64AB803502GENERAL ELECTRIC CONAVAL AND DRIVE TURBINE SYSTEMS DEPT
MIL-G-1899781349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
DG4MC1HPWRANAG81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
829N4-04FCRCW64467WEKSLER GLASS THERMOMETER CORP
SB24-3PFP-RWBX64467WEKSLER GLASS THERMOMETER CORP
Technical Data | NSN 6685-00-989-4669
Characteristic Specifications
ACTUATION TYPE BOURDON TUBE
SCALE TYPE SINGLE
SCALE NAME PRESSURE
SCALE RANGE+0.0 TO +100.0 POUNDS PRESSURE PER SQUARE INCH
SCALE ACCURACY1 PCT OF RANGE SPAN
GRADUATION UNIT10.0 POUNDS PER SQUARE INCH
SCALE SMALLEST INCREMENT1.0 POUNDS PER SQUARE INCH
SCALE INSCRIPTION/BACKGROUND COLORBLACK MARKINGS ON WHITE BACKGROUND
DIAL SIZE4-1/2 IN. DIA
POINTER TYPE INDICATING
ADJUSTABILITY ADJUSTABLE
POINTER COLOR BLACK AND RED
CASE MATERIAL ALUMINUM
CASE SURFACE TREATMENT ENAMEL
OVERALL DIAMETER4.969 INCHES NOMINAL
OVERALL DEPTH2.406 INCHES NOMINAL
PROTECTIVE CRYSTAL MATERIAL PLASTIC
CONNECTION QUANTITY2
CONNECTION TYPE EXTERNAL
CONNECTION LOCATIONZ ANY ACCEPTABLE
CONNECTION SIZE0.250 IN. TUBE
MOUNTING METHOD SURFACE
CONNECTOR TYPE VENT NOT PROVIDED
NONDEFINITIVE SPEC/STD DATAB DESIGN AND A TYPE