Part Details | INDICATING TEMPERATURE CONTROL
6685-01-122-1709 A device composed of one or more control-actuating mechanisms, one or more switchs, and graduated scales or other indicators. It is designed to measure and control temperature in ovens, furnaces, and the like, through perception of a sensing element connected to the control. Excludes SWITCH, THERMOSTATIC(00451) and THERMOSTAT, FLOW CONTROL(16516).
Alternate Parts: MPL904415, MPL90441-5, T80002405, T-8000-2405, 2728506, 27-2850-6, 2728506, 27-2850-6, 272850405, 27-2850-405, 272850405, 27-2850-405, T8000, T-8000, 6685-01-122-1709, 01-122-1709, 6685011221709, 011221709
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | NOV 15, 1981 | 01-122-1709 | 05662 ( CONTROL, TEMPERATURE, INDICATING ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-01-122-1709
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| MPL90441-5 | 90598 | ENGINEERED AIR SYSTEMS INC.DBA DRS SUSTAINMENT SYSTEMS |
| T-8000-2405 | 1MN13 | JOHNSON CONTROLS GOVERNMENT SYSTEMSLLC |
| 27-2850-6 | 4G075 | JOHNSON CONTROLS, INC.DBA JOHNSON CONTROLS |
| 27-2850-6 | 32242 | JOHNSON CONTROLS, INC.DBA JOHNSON CONTROLS |
| 27-2850-405 | 4G075 | JOHNSON CONTROLS, INC.DBA JOHNSON CONTROLS |
| 27-2850-405 | 32242 | JOHNSON CONTROLS, INC.DBA JOHNSON CONTROLS |
| T-8000 | 32242 | JOHNSON CONTROLS, INC.DBA JOHNSON CONTROLS |
Technical Data | NSN 6685-01-122-1709
| Characteristic | Specifications |
|---|---|
| POWER SOURCE | EXTERNAL |
| INCLOSURE TYPE | ENCASED |
| MAXIMUM OVERALL LENGTH | 3.070 INCHES |
| MAXIMUM OVERALL WIDTH | 3.750 INCHES |
| MAXIMUM OVERALL HEIGHT | 5.250 INCHES |
| OPERATING TEMP RANGE | -10.0 TO +120.0 DEG FAHRENHEIT |
| MOUNTING METHOD | BULKHEAD |
| SPECIAL FEATURES | PNUEMATIC TEMPERATURE CONTROL WHICH OPERATES WITH A 25 PSIG MAXIMUM REGULATED AIR SUPPLY;CONTAINS TWO GAGES;ONE TO MONITOR INLET THE OTHER TO MONITOR CONTROL PRESSURES;HAS A 0-4 PSI SENSITIVITY PER DEG. F.;TEMPERATURE ADJUSTMENT IS CONCEALED;SURFACE MOUNTED;AMBIENT TEMPERATURE OPERATING RANGES FROMMINUS 10 DEG. F. TO +300 DEG. F.;TEMPERATURE INCLUDED WITH DIAL MARKINGS OF 2 DEG. F. PER CONTROLING RANGE;FURNISHED WITH CONTROL ARE 4 1/8 IN PIPE PLUGS;2 ELBOWS;2 ORIFACE FITTINGS;2 NO 10X1 3/4 IN MOUNTING SCREWS;CAPILLARY TUBE AND BULB IS STAINLESS STEEL AND FULLY COMPENSATED;BULB IS 4 IN LONG;CAPILLARY TUBE IS 8FT LONG |
| END ITEM IDENTIFICATION | LGM30 MISSILE SYSTEM |
| SUPPLEMENTARY FEATURES | REVERSE ACTING;SPECIAL BLUB |
| TYPE/MODEL DESIGNATION | T-8000 |