Part Details | HUMIDITY CONTROL
6685-01-483-1283 A device composed of a control-actuating mechanism, an absorption element, and a switch for automatic controlling of humidity in rooms, compartments, and the like. May include an indicator.
Alternate Parts: HTR400, HTR-400, HTR400, HTR-400, HTR300, HTR-300, 6685-01-483-1283, 01-483-1283, 6685014831283, 014831283
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | MAR 16, 2001 | 01-483-1283 | 05661 ( CONTROL, HUMIDITY ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-01-483-1283
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| HTR-400 | 27970 | GE INFRASTRUCTURE SENSING, LLCDBA GE SENSING & INSPECTION |
| HTR-400 | 17466 | GE KAYE INSTRUMENTS INC |
| HTR-300 | 17466 | GE KAYE INSTRUMENTS INC |
Technical Data | NSN 6685-01-483-1283
| Characteristic | Specifications |
|---|---|
| MAXIMUM OVERALL WIDTH | 7.800 INCHES |
| MAXIMUM OVERALL HEIGHT | 13.500 INCHES |
| SENSING ELEMENT TYPE AND LOCATION | THERMOCOUPLE INTERNAL |
| OPERATING TEMP RANGE | +25.0 TO +400.0 DEG CELSIUS |
| MOUNTING METHOD | PLATFORM |
| SPECIAL FEATURES | ITEM AKA: DRY WELL TEMPERATURE REFERENCE; WGT: 18 LBS; DIM: 12.5" DEPTH; OPERATING TEMPERATURE: 5 - 50 DEG C;SET POINT ACCURACY: +/- 0.2 DEG C TO 300 DEG C, +/- 0.3 DEG C AT 400 DEG C; SETPOINT STABILITY +/- 0.02 DEG C/DAY TO 300 DEG C, +/- 0.05 DEG C/DAY TO 400 DEG C; DISPLAY RESOLUTION +/- 0.01 DEG C OR F; DISPLAY TYPE: LED, CENTIGRADE OR FAHR.; TYPICAL WARM-UP TIME: 5 MIN AMBIENT TO 90 DEG C, 3 MIN: 90 TO 125 DEG C, 25 MIN: AMBIENT TO 350 DEG C; TYPICAL COOL DOWN TIMES: 20 MIN: 125 TO 90 DEG C, 15 MIN: 350 TO 270 DEG C; FAULT PROTECTION: SENSOR BURNOUT PROTECTION, OVER TEMPERATURE THERMAL CUTOUT, ELECTRICAL FUSE: 115V, 6A; 230V, 3A; WELL DIMENSIONS: 2 REFERENCE WELLS AT 6.7MM (0.265") DIA. X 127MM (0.265") DIA. X 127MM (5") DEEP 8 CALIBRATION WELLS AT 9MM (0.354") DIA. X 155MM (6.1") DEEP; CALIBRATION WELL CAPACITY: 24 OR 32 DEPENDING ON WIRE SIZE |