NSN 6685-01-511-9504

Part Details | DIAL INDICATING PRESSURE GAGE

6685-01-511-9504 An instrument designed to measure air, gas, fluid, and vapor pressure by means of an internal pressure sensitive element (bellows, bourdon tube, transducer/transmitter and the like) which transmits energy, by direct linkage, to the indicating pointer of a scale or a digital display, calibrated in units of pressure. It may include a temperature equivalent scale. For items that do not have an internal pressure sensitive element see INDICATOR, PRESSURE.

Alternate Parts: 25224, 25-224, 6685-01-511-9504, 01-511-9504, 6685015119504, 015119504

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66AUG 19, 200301-511-950407428 ( GAGE, PRESSURE, DIAL INDICATING )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-01-511-9504
Part Number Cage Code Manufacturer
25-22462091NOSHOK, INC.
Technical Data | NSN 6685-01-511-9504
Characteristic Specifications
ACTUATION TYPE DIAPHRAGM
ACTUATING ELEMENT MATERIAL PHOSPHOR BRONZE
SCALE TYPE DIAL
SCALE NAME POUNDS PRESSURE
SCALE RANGE+0.0 TO +10.0 POUNDS PRESSURE PER SQUARE INCH
SCALE ACCURACYPLUS OR MINUS 1.5 % FULL SCALE
GRADUATION UNIT1.0 POUNDS PER SQUARE INCH
SCALE SMALLEST INCREMENT1.0 POUNDS PER SQUARE INCH
SCALE INSCRIPTION/BACKGROUND COLORBLACK FIGURES,WHITE BACKGROUND
DIAL SIZE2.5 IN DIAMETER
SCALE MARKINGAMARK PER TENTH POUND,NUMBERED MARK EVERY LB
POINTER TYPE INDICATING
ADJUSTABILITY NONADJUSTABLE
POINTER COLOR BLACK
SCALE NAME FOR WHICH POINTER IS DESIGNED POUNDS PRESSURE
POWER SOURCE EXTERNAL
OVERALL DIAMETER2.500 INCHES NOMINAL
MATERIAL PLASTIC ACRYLONITRILE-BUTADIENE-STYRENE (ABS)
PROTECTIVE CRYSTAL MATERIAL PLASTIC, METHYL-METHACRYLATE
CONNECTION QUANTITY1
CONNECTION TYPE EXTERNAL
CONNECTION LOCATION BACK, CENTER
CONNECTION SIZE0.250IN NPT
MOUNTING METHOD SCREW
MOUNTING CONNECTION LOCATION BACK, CENTER
MOUNTING HOLE QUANTITY1
CONNECTOR TYPE VENT NOT PROVIDED
SPECIAL FEATURES1 SCALE IN H2,PSI,BRASS CENTER BA K CONNECTION,ZINK PLATED STEEL PANEL MOUNT CLAMP,ASME GRADE A ACCURACY WORKING PRESSURE LIMITATIONS:DYNAMIC PRESSURE LIMITED 60% DIAL RANGE STATIC PRESSURE,WHERE NO SHARP FLUCTUATION OCCUR,LIMITED 90% DIAL RANGE,AMBIENT TEMP 0/140 DED F,MEASURED MEDIA SHOULD NOT EXCEED 140 DEG F,OVER PRESSURE PROTECTION AND RECALIBRATOR AVAILABLE AS OPTIONS
FUNCTIONAL DESCRIPTIONLOW PRESSURE DIAPHRAM TEST GAUGE