Part Details | MECHANICALLY COOLED BEVERAGE DISPENSER
7310-00-151-6525 An electrically-operated item designed to mix, cool and dispense carbonated and/or non-carbonated beverages. It may have one or more containers designed to afford continuous visual indication of beverage being dispensed. The item may be equipped with an agitation system for pulpy fruit juices, and may have an aeration system for non-foaming beverages.
Alternate Parts: A4L3, 417 354 000, 417 354 000, 5000, KK16683, MILD43738, MIL-D-43738, A4L3, 416306300, 416306-300, VPH204A, VPH-204A, 7310-00-151-6525, 00-151-6525, 7310001516525, 001516525
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
73 | APR 14, 1971 | 00-151-6525 | 32690 ( DISPENSER, BEVERAGE, MECHANICALLY COOLED ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 7310-00-151-6525
Part Number | Cage Code | Manufacturer |
---|---|---|
A4L3 | 92435 | ALCO STANDARD CORPALCO FOOD SERVICE EQUIPMENT CO |
417 354 000 | 6W611 | CLELAND SALES CORP |
417 354 000 | 51267 | IMI CORNELIUS INC. |
5000 | 58409 | KENCO PRODUCTS CORP |
KK16683 | 28447 | KESSEL KITCHEN EQUIPMENT CO INC |
MIL-D-43738 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
A4L3 | 3Z046 | WILSHIRE CORP |
416306-300 | D9182 | ZF INDUSTRIEANTRIEBE WITTEN GMBH |
VPH-204A | D9182 | ZF INDUSTRIEANTRIEBE WITTEN GMBH |
Technical Data | NSN 7310-00-151-6525
Characteristic | Specifications |
---|---|
DISPENSING PRESSURE TYPE | PRESSURE DEMAND |
DISPENSER TYPE | COUNTER TOP |
DRAW-OFF DEVICE TYPE | GLASS FILLER |
QUANTITY | 4 |
REFRIGERATION UNIT CABINET | NOT INCLUDED |
CONDENSER TYPE | H ANY ACCEPTABLE |
CONDENSER COOLING TYPE | AIR |
CURRENT TYPE | AC |
VOLTAGE RATING | 120.0 VOLTS NOMINAL |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
PHASE | SINGLE |
COOLANT TYPE | E ANY ACCEPTABLE |
MATERIAL AND LOCATION | BASE STEEL, CORROSION RESISTING |
USAGE DESIGN | CARBONATED BEVERAGE |
FEATURES PROVIDED | CARBONATOR AND SYRUP TANK |
SPECIAL FEATURES | W/QUICK DISCONNECT BALL LOCK FITTING FOR CO2 TANK,SYRUP TANK AND WATER CONNECTION,SYRUP TANKS NOT FURNISHED |
NONDEFINITIVE SPEC/STD DATA | 4 CLASS AND 1 SERVICE AND A STYLE AND 1 SIZE AND II TYPE |
SUPPLEMENTARY FEATURES | 2 EA NSN 8120-00-151-9749 (CO2 CYLINDER EMPTY) REQUIRED AS SEPARATE ITEM FOR HOOK-UP TO CARBONATOR |